GaseraModel PA 301 -Ultra-High Performance Photoacoustic Detector for Solid, Semi-Solid and Liquid Samples

SHARE

The PA301 photoacoustic FTIR accessory improves laboratory productivity and safety by enabling extremely versatile and rapid analysis of solid, semi-solid, and liquid samples in any form without sample preparation. The insensitivity to sample surface morphology, the depth profiling capabilities, and contactless measurement provide wide applicability in many areas of chemical and biological research which no other single accessory can match.

Most popular related searches
  • No sample preparation
  • Contactless measurement
  • 100x faster than other PAS solutions

Due to the ultra-high sensitivity of the Gasera novel cantilever sensor, high quality spectra can be obtained in just seconds unlike in other available photoacoustic accessories. In fact the PA301 is over 100x faster that other competing PA solutions in the market. Furthermore, ambient air can be used as the carrier gas to obtain a signal-to-noise ratio (SNR) that is still significantly better compared to other commercial photoacoustic detectors used with helium carrier gas.

The quickness and the ease of use make the PA301 a must-have accessory for every lab!

Ultra-high performance photoacoustic detector

  • Improves laboratory productivity and safety
  • For solid, semi-solid and liquid samples
  • The quickness and the ease of use

Versatile analysis with ultra-sensitive photoacoustic FTIR accessory

Baseplate options

All major brands are supported

Connection to commercial FTIRs is provided by the baseplate

UV-region, IR-region, NIR- region

Spectral region is defined by the window material (user changeable)

Spectrum normalization

by carbon black reference. Comes with different size sample cups.

  • Photoacoustic detector with focusing mirror
  • Optical cantilever microphone with built-in laser readout interferometer
  • Removable sample cups for solid, semi-solid, and liquid samples
  • Carbon black reference
  • Vibration isolated detector mounting
  • Digital Signal Processing -module
  • Power supply (+12 VDC)
  • Cables to connect the modules and to connect to the FTIR instrument
  • Gas connector for purge gas with automatic valve contol and built in flow meter
  • Detector manual
  • Storage case
  • Minimum detectable pressure variation in the PA301 sample cell: 2 μPa/√Hz  (RMS)
  • Microphone sensitivity: Approx. 10 V/Pa
  • Rapid sample change without breaking the purge seal
  • Analog interface: BNC cable to detector input on the FTIR
  • Analog output: +/- 3.3 VDC interferogram signal
  • DSP analog output gain range: 0.02 – 20 in 10 step
  • Spectral range de?ned by window material (from UV to far-IR)
  • Maximum sample size: 10 mm diameter, 9 mm height
  • Helium purge with automatic purge valve operation
  • Dark samples (eg. bitumen, rubber, etc.)
  • Pharma quality control
  • Soil samples
  • Paper and wood analysis
  • Oil analysis
  • Tissue samples
  • Food analysis
  • Forensics
  • Cosmetics
  • Art Conservation
  • Polymeers
  • Paint and pigment analysis
  • Gemstones