Wi.Tec-Sensorik GmbH
  1. Companies
  2. Wi.Tec-Sensorik GmbH
  3. Products
  4. ULTRA.sens - Model AK100 - H2S Gas ...

ULTRA.sensModel AK100 -H2S Gas Measurement Module

SHARE

The ULTRA.sens is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. By using two UV-LEDs 2 gases can be detected simultaneously. With this approach, 2 measuring ranges from ppm to Vol.-% can also be realized. In the spectral range from 200 nm to 500 nm, nitrogen oxides (NO+NO2), aromatic hydrocarbons, hydrogen sulphide, ozone, sulphur dioxide and chlorine can be reliably detected with this novel sensor platform.

Most popular related searches
  • High dynamic range
  • Fast response time
  • Applicable for continuous measurements
  • Different Interfaces (RS232, CANbus)

General features

  • Measurement principle : Non-dispersive ultraviolett (NDUV); dual beam
  • Measurement range : see list of measurement ranges
  • Gas flow : 0.1 – 1.5 l/min
  • Dimensions : 300mm x 100mm x 81mm
  • Weight : approx. 1670g
  • Tube connector : 4/6mm tube
  • Lifetime of UV radiation source : > 8 000h1

Measuring response* :

  • Warm-up time : 1 min (initial),
  • Response time (t90) : 1.5s – 15s4
  • Detection limit (3·σ) : < 1 ppm5
  • Linearity error : < ± 1 %F.S.
  • Repeatibility : ± 0.5 %F.S.
  • Long term stability (zero) : < ± 1 %F.S. /24h
  • Long term stability (span) : < ± 1 %F.S. /month
  • Temp. Influence zero : < 1 %F.S. /10K
  • Temp. Influence span : < 2 %F.S. /10K6
  • Cross sensitivity : < 2 %F.S. 7
  • Pressure influence : < 1.5%/10h of reading

Electrical inputs and outputs :

  • Supply voltage : 24 (15 – 30) VDC
  • Supply current (peak) : < 0.4A
  • Power consumption (average) : < 7.5W
  • Digital output signal : RS 232 (ASCII) or CAN bus

Climatic conditions :

  • Operating temperature* : 5 – 45 °C9
  • Storage temperature : -20 – 60 °C
  • Air pressure : 800 – 1200 hPa (mbar)
  • Ambient humidity : 0 – 95 % rel. humidity (not condensing)