Delta M Corp.
  1. Companies
  2. Delta M Corp.
  3. Products
  4. Versa-Switch - Model VS5100 - Premium ...

Versa-SwitchModel VS5100 -Premium Flow/Level/Temperature Switch

SHARE

Simple field adjustable thermal differential switch for mass flow, level, and/or temperature of liquids or gasses with time delay adjustable from 0 to 300 sec. Wide operating temperature range -100°F to +850°F (-70°C to +458°C). User configurable operating power 110VAC, 220VAC, or 24VDC. Removable, plug in electronics. Can be configured with 2 independent outputs, such as level or mass flow with temperature or two mass flow rates. Level response time of .1 to 1 second on wetting, media dependent Flow response time of .5 to 10 seconds, media dependent Can be used for either gas or liquid applications including interface detection. Self heating sensor design improves repeatability. No separate heater to fail or slow response time. Two Year Workmanship Warranty

Most popular related searches
SENSORS

Type:
Thermal Differential, dual RTD sensors with no separate heater

Process Connection:
Standard 0.75 inch MNPT
Optionally 0.5 inch and larger MNPT and various other process connections such as sanitary and flanges

Insertion Length:
Standard 2.0 inch
Optionally 0.5 inch or greater

Operating Temperature Range:
Standard -100°F to 390°F (-70°C to +200°C)
Medium Temperature to +572°F (+300°C)
High Temperature to +850°F (+458°C)

Materials of Construction:
Standard 316L Series Stainless Steel
Optionally Hastelloy, Monel, Inconel and other exotic materials

Operating Pressure Range:
Standard to 3000 psia (207 bar)

ELECTRONICS

Power:
Standard Field selectable 110VAC, 220VAC, or 24VDC at 3 watts (No heater power required) Optionally 24VAC

Operating Temperature Range:
Standard -40°F to +140°F (-40°C to +60°C)
Optionally Remote electronics for use in medium and high temperature environments

Outputs:
Independent primary relay DPDT and secondary relay SPDT, contacts rated at 5 amp, 250 VAC with fail safe capability; built in time delay 0 to 300 seconds for each channel.

Self-Test:
Integral and automatic during power up.

Failure Alarm Option:
Continuous monitoring circuit to alarm should a failure condition of any sensor, component, wiring, or power occur. (Uses second channel of the VS5100)

Enclosure:
Explosion proof; NEMA 3, 4, 4x,7, and 9; CSA, FM, UL

INSTRUMENT

Operating Range:
Flow 0.01 to 5.0 fps in oil,2.5 fps in water and 0.1 to 500 fps in gases. Level change as small as .03 inch.
Temperature -70° C to +458° C +/- 1° C.

Response Time:
Media dependent 0.5 to 10 seconds.

Available Approvals:
CSA Class 1 Div. 1 Groups B,C,&D Class 2
Div. 1 E,F,&G with T4A Temp rating.