GrayWolf - Model PC-5000 Series -Wall-Mounted Particle/Mass Monitor Plus
Use PC-5000/5s as stand-alone, continuous particulate/IAQ meters. Or plug into mobile computers or into sophisticated AdvancedSense systems for simultaneous connection with GrayWolf’s DirectSense probes.
Most popular related searches
stainless steel enclosure
CO2 sensor
particle mass monitoring
particle sizing
particulate meter
temperature probe
IAQ meter
HEPA filter
environmental sensor
flow control
- Easily download data from the PC-5000/5 using the included WolfSense PC Software to create high quality trend/bar graphs/tables with WolfSense’s advanced organizational features or simply export to Microsoft Excel.
- Optionally add Advanced Report Generator software for extremely efficient, automated reporting of particle count/concentration data.
- Easy-to-read 4.3″ (10.9 cm) WQVGA (480x272) color touch screen.
- Offering 6 channels of simultaneous particle counting, this unit displays both particle counts and (PM) mass concentration (µg/m3 ). PM0.5, PM1.0, PM2.5, PM5.0, PM10 and TSP may be concurrently displayed and logged.
- Optionally add simultaneous %RH and °C/°F (PC-5000) plus TVOCs and/or CO2 (PC-5005). And even more parameters via interface to AdvancedSense Pro or tablet PC and DirectSense Probe(s).
- Simultaneously displays calculated PM2.5, PM10 and TSP mass concentration in μg/m³ (also PM0.5, PM1.0 and PM5.0).
- Measures 6 channels of simultaneous particle count data (0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm)
- Integrate into a building automation system using Ethernet, USB, RS232 or (optional) Wireless 802.11 b/g or RS485
- Access readings via Modbus RTU or (optional) cloud-based GrayWolfLive
- Optional %RH and temperature probe
- Optional TVOC and/or carbon dioxide sensors; highly accurate PID and NDIR (PC-5005 only)
- Measures particulate 0.3 μm to 25 μm
- 0.1 CFM (2.83 LPM) flow rate via precision, brushless internal pump
- Large easy-to-use icon driven color touch screen display
- As a stand-alone, store up to 45,000 sample records, in up to 1000 location files
- Download logged readings to WolfSense PC for analysis and/or export to CSV Format (Excel)
- Internal audible alarms, all parameters
- User-friendly field calibration
- Wall-mounting stainless steel enclosure
- 2 year limited warranty
- Size Range 0.3 to 25μm
- Size Channels Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm Custom binning available
- Flow rate 0.1 CFM (2.83 LPM)
- Concentration Limit >4,000,000 Particles/ft³ @ 5% coincidence loss
- Light Source Long life laser diode
- Counting Efficiency 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
- Zero Count <1 count/5 minutes (<2 particles/ft³) (per ISO 21501-4 & JIS)
- Count Modes Automatic, manual, beep, cumulative/differential counts or mass concentration
- Count Alarms 1 to 9,999,999 counts
- Carbon Dioxide (Optional) 0 to 5,000 ppm ±65ppm ±3% rdg. (PC-5005 only)
- Relative Humidity/ Temperature (Optional)
- 15 to 90 %RH ±2%RH,
- 32 to 122 °F (0 to 50 °C) ±1ºF (0.5ºC)
- TVOCs (Optional) 0 to 50ppm range, <5ppb L.O.D. (PC-5005 only)
- Display 4.3” (10.9 cm) WQVGA (480x272) color touch screen
- Vacuum Source Internal brushless pump with automatic flow control
- Filtered Exhaust Internal HEPA filter
- Number of Channels 6 for particulate, plus 2 for optional TRH (PC-5000), plus 2 additional for optional sensors on the PC-5005
- Custom Size Channels Calibration for custom particle size channels available
- Audible Alarm Adjustable built-in alarm
- Recipes 50 user-configurable recipes
- Communication Modes Serial (for interface with AdvancedSense Pro, WP, Tablets and data download to WolfSensePC), USB for calibration and firmware updates RS-232 Modbus and Ethernet hardware is standard
- Optional Communication Modes
- RS-485 may be substituted for RS-232 (specify with order).
- Wireless 802.11 b/g (with antenna) is optional.
- GrayWolfLive cloud-based interface software is optional.
- Alarm Alarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow
- Standards ISO 21501-4 and JIS B9921
- Factory Calibration Recommended annually. NIST traceable (cert optional)
- External Surface Stainless steel
- Dimensions (L x W x H) 5.2" x 2.3" x 8.25" (13.3 cm x 5.9 cm x 21 cm) incl. barb fittings (9.5", 24 cm H w/isokinetic inlet)
- Weight 3.5 lb (1.6 kg)
- Included Accessories Quick start guide, operating manual on USB flash drive, isokinetic probe, purge filter, WolfSense® PC data download and basic report generation software, USB cable, power supply (spec US, UK or Euro plug)
- Additional Optional Accessories: Calibration hood, printed manual, spare battery, isokinetic probes, WSARG Advanced Report Generator
- Buffer Memory 45,000 sample records (rotating buffer) including particle count data, environmental data, locations and times.
- Scrollable on screen or printout
- Sample Locations Up to 1,000 locations 20 characters long (unlimited locations 256 characters long, when interfaced to
- AdvancedSensePro/WolfPack/tablet with WolfSense LAP)
- Sample Time 1 second to 99 hours
- Power 110 to 240 VAC 50/60 Hz universal in-line power supply
- Operating Conditions 41º to 104ºF (5º to 40ºC)/20% to 90%RH non-condensing
- Storage Conditions 32º to 122ºF (0º to 50ºC) / Up to 98%RH non-condensing
- Warranty 2 years limited (1 year on internal pump and optional TVOC, CO2 sensors)