The Aspirated Radiation Shield provides maximum sensor protection from incoming short wave and outgoing long wave radiation. The shield employs a triple walled intake tube and multiple canopy shades to effectively isolate the sensor from precipitation and solar radiation. A continuous duty DC blower provides constant flow of ambient air over the sensor. A tachometer output may be used to monitor blower operation. A variety of temperature and relative humidity probes are available.
Most popular related searches
aspirated radiation shield
radiation shielding
relative humidity probe
temperature and humidity probe
humidity probe
ambient air
ambient air sensor
blower
tachometer
air sensor
- Radiation Error:
- Ambient Temperature: 0.2 °C (0.4°F) RMS @ 1000 W/m2
- Delta T: 0.05 °C (0.1°F) RMS with like shields equally exposed
- Aspiration Rate:
- 5 to 11 m/s (16 to 35 fps) depending on sensor
- Power Requirement:
- 12 to 14 VDC @ 500 mA
- Construction:
- UV stabilized white thermoplastic shield, aluminum mounting bracket, stainless steel U-bolt
- Dimensions:
- Overall: 33 cm (13 in) H x 20 cm (8 in) Dia
- Shield: 70 mm (2.8 in) Dia x 12 cm (4.7 in) L
- Weight:
- Net Wt: 1.1 kg (2.5 lb) Shipping Wt: 2.7 kg (6 lb)