APTwater LLC

Aftermarket Sales & Service

SHARE

We supply scheduled preventative maintenance services during the contracted timeframe of our HiPOx, PulseOx, and ARoNite systems located at client sites to improve operation efficiencies and ensure a longer service life of our treatment systems. The cost of these visits will be billed on a Time and Materials (T&M) basis.



Most popular related searches

Our standard scope of preventative maintenance services to be performed on our installed HiPOx systems includes but is not limited to the following:

General
  • Reagent level or inventory inspection
  • Leaks or unusual noises inspection.
  • Oxygen Dewar and nitrogen cylinder levels inspection.
  • Motor bearings maintenance
Oxygen/Ozone System
  • O3 distribution rotometers.
  • Injectors and solenoid valves.
  • Ozone Generator
  • Valves
  • Ambient ozone analyzers
Cooling System
  • Coolant filter
  • Condenser heat exchanger coils.
  • Replace coolant.
  • Chiller refrigeration system
Gas Vent System
  • Reagent level or inventory inspection
  • Leaks or unusual noises inspection.
  • Oxygen Dewar and nitrogen cylinder levels inspection.
  • Motor bearings maintenance
Hydrogen Peroxide System
  • Peroxide tank.
  • Peroxide flow meter(s).
  • Peroxide metering pump check valves
  • Peroxide in-line filter.
Electrical System Process
  • Check effluent for ozone and peroxide concentrations.
  • Inlet bag filters inspection.
  • Mixers inspection.
HiPOx System Preventative Maintenance Scope

For our PulseOx systems, we provide periodic preventive maintenance on a Time and Materials (T&M) basis in accordance with our standard Labor Rates and Reimbursables Schedule when requested via purchase order by the customer. Service Maintenance Agreements are available at an additional cost. Our standard scope of preventative maintenance services to be performed on our installed PulseOx systems includes but is not limited to the following:

  • Record current system operating data on log sheet
  • Check/record valve injection sequence timing
  • Check distribution tubing/fittings for leaks
  • Check hydrogen peroxide lines for leaks and gassing
  • Check/fill hydrogen peroxide tank level
  • Check chemical pump operation
  • Check air compressor lines/fittings for leaks
  • Check air pressure and flow
  • Check/replace trailer ventilation intake filter
  • Clean dust/debris from cabinet, fans, and air compressor housing
  • Inspect all electrical components and tighten wiring as needed
  • Adjust process pressures and flow rates as needed
  • Perform rebuild kit on oxygen compressor
  • Replace PSA compressor diaphragm
  • Perform minor service kit, piston rings, springs, etc on air compressor
  • Valve assembly service kit for air compressor
  • Replace ozone sensor
  • Check all pressure switches, flow switch, and pressure relief valves
  • Major replacement kit on air compressor, piston and rod assembly