Unicon Engineers

GD Testing Services

SHARE

Unicon is equipped to carryout GD testing of any make ESPs with more than 35 years experience in the field.

Most popular related searches

Why GD Testing

  • Improve the performance of ESP
  • Meet the emission legislation by increasing equipment collection efficiency.
  • Drive down the operational cost with improved quality.
  • Cost Effectiveness.
  • Separate shutdown is not required for implementation.
  • Reduce the shutdown time.
Test ProcedureOptimizing Air Flow in ESP Chambers

To ensure optimal air flow in ESP chambers, we follow a precise process. We run ID, FD, and PA air fans at suitable loadings and record fan loadings and furnace draught for consistency. Velocity measurements are taken using a vane type anemometer.

Velocity Measurements:

Measure velocities between the first and second field. Mark points on the trailing edge of the first field’s collecting electrodes, spaced 1000mm apart with a 500mm gap from the top and bottom, and take readings at every alternate electrode spacing.

Trial and Adjustment:

Conduct multiple trials to achieve acceptable gas distribution, making adjustments to deflector/throttling plates based on test results. Repeat the process until the desired distribution is achieved.

Acceptance Criteria:

Ensure the coefficient of variation for gas distribution is less than 20%.

This methodical approach guarantees efficient gas distribution and enhances the ESP chamber`s performance.