Flue Gas Articles

  • Flue gas treatment plant chemical tanks - Case Study

    Specifications: AISI 316Ti SS, cover with pneumatic piston, empty weight: 2200 kg/each Scope of work: Manufacturing and transportation ...


    By ASTIM A.S.

  • Large elements for CHP on a trip through Helsingør`s streets

    A 27 meter long condenser was the largest of the many steel and glass fiber elements that were transported from the state port to the construction site on the outskirts of the city. The renewal of Helsingør Kraftvarmeværk really put its mark on Helsingør's streets yesterday ...


    By GCER

  • Axetris achieves Silver Gas Award 2013

    Here the original text from G&I: „The Axetris AG LGD F200 self-contained laser gas detector module is designed for integration by original equipment manufacturers (OEMs) of selective catalytic reduction (SCR) systems and monitoring equipment and is based on proprietary technology- enhanced tuneable diode laser spectrometry. The OEM module can measure concentrations from well under ...


    By Axetris Ag

  • QChem flue gas cooler - Case study

    Project: Qatar Chemical Company (Q-Chem) Location: Qatar Engineer: In-House Applicator: Cape East Refractories Sauereisen Representative: Virtual Scientific Products: High Temperature membrane No. 89 Lightweight Acidproof Concrete No. 54LW ...


    By Sauereisen Inc.

  • Ca removal and Mg recovery from flue gas desulfurization (FGD) wastewater by selective precipitation

    Selective removal of Ca and recovery of Mg by precipitation from flue gas desulfurization (FGD) wastewater has been investigated. Thermodynamic analysis of four possible additives, Na2CO3, Na2C2O4, NaF and Na2SO4, indicated that both carbonate and oxalate could potentially provide effective separation of Ca via precipitation from Mg ...


    By IWA Publishing

  • TurboScrubber® & TurboStripper® ‘TURBOCC’ Technology, for Flue Gas Cleaning & Carbon Capture System for Enhanced Plant Growth

    The plant would be supplied in a number of preassembled skid mounted packages for installation and connection on site. Typically these packages would comprise:  TurboScrubber®, water sump, recirculation pumps (run & standby), local water circulation pipework, forced or induced draft flue gas fan and local flue gas ductwork.  TurboStripper®, water sump, recirculation ...

  • Amager Bakke / Copenhill Copenhagen, Denmark - Case study

    Copenhagen’s state of the art plant sets new standards for environmental performance, energy production and waste treatment. Innovative technology and architecture integrate to form a future in which waste-to-energy plants are welcomed in any backyard. In year 2017, Copenhageners and visitors will witness a  ...


    By Babcock & Wilcox MEGTEC LLC

  • Case study - Bespoke Solutions

    PROJECT 5000kg/h animal remains incineration project in accordance with EU WID Makkah, Kingdom of Saudi Arabia PROJECT DESCRIPTION The purpose of the plant was to dispose of the animal waste associated with Hajj religious festi-val in Makkah Saudi Arabia. During the festival approximately 10,000 tonnes of waste is pro-duced in 4-5 days. Historically ...

  • Innovation drives flue gas treatment - Case study

    Sharing a common goal, experts in emissions monitoring and emissions abatement have formed a working partnership to develop innovative new materials for treating pollutants in flue gas emissions. ...


    By Gasmet Technologies Oy

  • Case study - Jämtlands Värme, Strömsund

    The boiler for Jämtlands Värme in Stromsund was built in 1987.  The old flue gas condenser, from another supplier, began leaking and needed to be replaced. Boiler: 10 MW Fuel: Bio fuels Condensor effect: 2 MW The boiler in Strömsund was built in 1987 and in 1994 it was equipped with a flue gas ...


    By Envibat AB

  • Case study - Novartis, Ireland

    Novartis is one of the leading medical industries. They chose Envibat’s technology for cleaning flue gas at one of their production plants in Ireland. The project was completed in June ...


    By Envibat AB

  • QinetiQ – Modular EU Compliant incineration package - Case Study

    TodaySure™ were commissioned to construct an Integrated Battlefield Support System Incinerator as part of a Ministry of Defence funded research programme, to demonstrate that waste management can be achieved in a responsible way, compliant with challenging environmental standards. Designed to meet the stringent requirements of the EU Waste Incineration Directive, the combustion chambers, ...

  • Coke Plant Scrubber Water Case Study

    Challenge For the production of coke, volatile constituents of the coal —including water, coal-gas, and coal-tar— are driven off by baking in an airless furnace at temperatures as high as 2.000 °C. The flue gas goes through an ammonia-based scrubbing process. The resulting scrubber water contain small coal-tar and other organic particles (1-250 micron) that cause scaling in ...


    By akvola Technologies

  • Simultaneous removal of Ni(II) and fluoride from a real flue gas desulfurization wastewater by electrocoagulation using Fe/C/Al electrode

    Large amounts of anions and heavy metals coexist in flue gas desulfurization (FGD) wastewater originating from coal-fired power plants, which cause serious environmental pollution. Electrocoagulation (EC) with Fe/C/Al hybrid electrodes was investigated for the separation of fluoride and nickel ions from a FGD wastewater. The study mainly focused on the technology parameters including anode ...


    By IWA Publishing

  • WESPS continue to deliver

    Compliance with the increasingly stringent air pollution regulations of recent years is not the only reason forwardthinking industry leaders are adopting more sophisticated gas cleaning and air pollution control strategies. The desire to achieve higher performance efficiencies, control costs in a competitive marketplace, and stay ahead of the regulatory compliance curve is another driver of ...


    By Beltran Technologies, Inc.

  • Advanced WESP designs assure superior gas cleaning performance

    Nowadays, many industries are facing formidable environmental challenges and there is a growing need for effective, economical gas cleaning and air pollution control equipment. Michael Beltran of Beltran Technologies, Inc. reports on a renewed interest in high-efficiency wet electrostatic precipitators (WESPs) and discusses their importance for controlling sulphuric acid mists and other ...


    By Beltran Technologies, Inc.

  • Lansing Generating Station, Unit 4 - Case study

    Alliant Energy Lansing, Iowa, USA Plant Description Pre-retrofit equipment 270 MW boiler Hot-side electrostatic precipitator (ESP) Selective catalytic reduction (SCR) Powdered activated carbon (PAC) Fabric filter Contract Order 2012 Commercial ...


    By Babcock & Wilcox MEGTEC LLC

  • The Right Mix for Clean Air

    Reducing air pollution is an increasingly important topic all around the world. Many governments—also in developing countries—set new limits for emissions such as nitrogen oxides in flue gas. Sulzer offers advanced mixing technology for flue gas cleaning. The installation in a large power plant shows that these high-performance mixers can cope with the most difficult requirements. ...


    By Sulzer Management Ltd

  • Fenton degradation of Cartap hydrochloride: identification of the main intermediates and the degradation pathway

    The advanced oxidation of Cartap hydrochloride (Cartap) promoted by the Fenton system in an aqueous medium was investigated. Based on total organic carbon, chemical oxygen demand and high-performance liquid chromatography, the oxidation of Cartap is quite efficient by the Fenton system. Its long chain is easily destroyed, but the reaction does not proceed to complete mineralization. Ion ...


    By IWA Publishing

  • Fenton degradation of Cartap hydrochloride: identification of the main intermediates and the degradation pathway

    The advanced oxidation of Cartap hydrochloride (Cartap) promoted by the Fenton system in an aqueous medium was investigated. Based on total organic carbon, chemical oxygen demand and high-performance liquid chromatography, the oxidation of Cartap is quite efficient by the Fenton system. Its long chain is easily destroyed, but the reaction does not proceed to complete mineralization. Ion ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you