To assess exposure at an industrial workplace UFP measurements were carried out. As part of a four-step approach starting with a paper risk-study in the second step NanoTracers were used to assess exposure from manufacturing processes vs. the local background levels. Using the mobile device specific spots in the manufacturing site could be identified that could be improved to reduce the exposure levels. As a next (third) step specific positions were identified to execute multi-day sampling of materials, to further pinpoint improvement opportunities.