Kurz Instruments, Inc.

Series 155 Adam Mass Flow Computer/Transmitter Brochure

S E R I E S155MASS FLOWCOMPUTERSINC.INSTRUMENTS©..KEY FEATURESEasy-to-use menu for display and set-up with HELP screens.Multipoint calibration factor for each METER.User-entered METER ID number and ?ow area.Automatic sensor out-of-tolerance indication, alarmand re-averaging for multipoint ?ow elements.Lagrangian polynomial calibration data interpolationfor maximum accuracy.User-selectable digital ?ltering for all input channels.Operating temperatures range -25°C to 60°C.Built-in ?ow totalizers and elapsed time. Non-Incendive Approval on all models.Paper tape printer.DESCRIPTIONKnown as ADAM™, these“Smart” Mass Flow Com -puters are state-of-the-art,microprocessor-based, ver -satile system transmitters.The various models operateone or more Kurz Mass FlowEle ments including Series410, 452, 454FT, 502, 504FT,510, 532, 522-UHP, 542, K-BAR 16, K-BAR 24, K-BAR2000, the Series IK-4200 Iso kinetic Sampling Systemsand the Series 730 ElectricRotary Ramp Control Valves.The Series 155 integrates thefunctions of ?ow and tem -perature measurement, ?ow totalization, alarms, data acquisition, input/outputcalibration and closed loop?ow control.Models are available tooperate up to 22 separatemass ?ow or temperatureelements. A METER may bede?ned to represent the out-put of a mass ?ow element orthe average value of severalmass ?ow or temperatureelements such as the K-BAR24 Multi-Point Insertion MassFlow Elements. The small erModel 155’s have two analog4-20 mA outputs; the largermodels support up to eight 4-20 mA outputs. All odelsin clude a convenient 2 line, 16 character display and 20button keypad to display themeasurements, input all cali-bration and set-up data, andperform input/output calibra-tion of each input and eachanalog output. In addition,each odel has a RS-232Ccom munication port whichallows a compatible PCto be used to thekeypad functions. Severalmodels may be con?gured fordual redundancy. Get the best — Get Kurz S E R I E S 1 5 5 M A S S F L OW C O M P U T E R SEcho type RS-232C communication port for terminal operation and setup.Optional NEMA 4, NEMA 4X, NEMA 7 and 19" EIA rack enclosures. Meets all the requirements for 40CFR 75, stack ?owmonitors (EPA Title IV) including ?ow interferenceand daily Drift Check (except 155Jr).Velocity Temperature Mapping (VTM) for wide ranging process temperature and velocity.Optional RS-232C data port on all models; RS-485 on 155C-2, 155E-2 and 155E-RM2.Choice of using optically isolated loop-powered orself-powered 4-20 mA outputs.Optional mass ?ow control of up to separate In-Line Mass Flow Elements.Optional automatic isokinetic particulate sampling of up to four sample streams.Optional “Flow Perfect” sensor array con?gurationcorrection factor with “Kick-Out Count” for multipoint averaging con?gurations.EMI Approvals: CE compliance.Optional pulsed ?ow totalizer outputs.Optional redundant con?guration using two Series155 Mass Flow Computers.Technician and user access codes for security.PAGE 224 hour clock/calendar.20 button keypad (built-in terminal).Up to 22 sensor inputs; mass ?ow rate, temperatureand 4-20 mA reference inputs.Ability to group one or more inputs as a METERand to de?ne a METER as the sum/difference ofother METERS, up to a maximum of 16 METERS.Up to eight 4-20 mA outputs.Up to eight 5-amp alarm relays.Kurz Instruments, Inc. 2411 Garden Road, Monterey, CA 93940 Tel 800-424-7356Fax 831-646-8901 www.kurzinstruments.com e-mail: sales@kurzinstruments.comTwo-line 16 character .display-English or Metric units (SFPM, SCFM, SCFH, PPH, °F SMPS, SCMM, SCMH, KGH,°C).,Built-in ?eld calibrators for all models.Identical software menus for all models.Easy input/output calibrationall digital .mmechofourTABLE 4: SERIES 155 PARENT NUMBERS,ENCLOSURE DESCRIPTION, SAFETY APPROVAL (Note 1)Model ParentNumber Number Enclosure Description Safety Approval155Jr 750101 NEMA 4X Fiberglass Ex nC II T4 (Cl. I , Div. 2, (Note 2) GPS. A, B, C, D, T4); CSA 155Jr-ExW 750105 NEMA 4/7, Aluminum Cl. I , Div. 1, GPS. B, C, D with window155A 750206 NEMA 4X Fiberglass Ex nC II T4 (Cl. I , Div. 2, (Note 2) GPS. A, B, C, D, T4); CSA155A-ExW 750208 NEMA 4/7, Aluminum Cl. I , Div. 1, GPS. B, C, D with window155B 750235 NEMA 4X Fiberglass Ex nC II T4 (Cl. I , Div. 2 (Note 2) GPS. A, B, C, D, T4); CSA155B-RM 750237 Rack-Mount, 19" EIA Ex nC II T4 (Cl. I , Div. 2(Note 2) GPS. A, B, C, D, T4); CSA155C-2 750257 NEMA 4 painted steel Ex nC II T4 (Cl. I , Div. 2(Note 2) GPS. A, B, C, D, T4); CSA155C-RM2 750258 NEMA 4 painted steel Ex nC II T4 (Cl. I , Div. 2(Note 2) GPS. A, B, C, D, T4); CSA155E-2 750272 NEMA 4 painted steel Ex nC II T4 (Cl. I , Div. 2(Note 2) GPS. A, B, C, D, T4); CSA155E-RM2 750278 Rack-Mount, 19" EIA Ex nC IIC T4 (Cl. I , Div. 2(Note 2) GPS. A, B, C, D, T4); CSANote 1: Refer to the outline drawings of the Series 155 Mass Flow Computer brochure fordimensions, net wt., and shipping wt., etc. All models have CE Compliance.Note 2: LCD/Keypad is mounted on cover, with weatherproof, ?exible polycarbonate overlay.SERIES 155 NOMENCLATURETerm DescriptionInput Current inputs to the Series 155 representing Kurz mass ?ow, temperatureChannel and ?ow control reference inputs. Input channels are labeled A, B…Flow A unique con?guration correction software algorithm for Insertion Perfect® Mass Flow Elements that is used with velocity arrays. Flow Perfect auto-matically corrects for velocity sensors that are “kicked-out” of the averagebecause readings are out-of-tolerance. Flow Perfect requires that ?eld calibration data for each velocity sensor be entered in the Series 155.METER A METER may be Mass Flow Meter, Temperature Meter, a reference Mass Flow Meter representing a ?ow control set-point, or a Mass FlowMeter representing the sum and/or difference of several Mass Flow Meters. A METER can be assigned an I.D., area, correction factors, outputs, alarms, etc.TABLE 1:SERIES 155 INPUT/OUTPUT/POWER CAPABILITIESInput Number Optional Maximum Current (mA)Model Power of Input Analog Max.Number (Note 1) Channels Outputs Meter 40°C 50°C 60°C155Jr AC 2 1,2 4 625 575 525155Jr DC 6 1,2 8 3,000 3,000 3,000155A AC 6 1,2 8 1,725 1,625 1,525155A DC 6 1,2 8 3,000 3,000 3,000155B AC 6 1,2 8 3,400 3,200 3,000155B-RM AC 6 1,2 8 3,400 3,200 3,000155B-RM DC 6 1,2 8 3,000 3,000 3,000155C-2 AC 22 1,2,4,6,8 16 6,000 5,500 4,550155C-2 DC 22 1,2,4,6,8 16 11,000 11,000 11,000155E-2 AC 22 1,2,4,6,8 16 11,000 11,000 11,000155C-RM2 AC 22 1,2,4,6,8 16 6,000 5,500 4,500155C-RM2 DC 22 1,2,4,6,8 16 11,000 11,000 11,000155E-RM2 AC 22 1,2,4,6,8 16 11,000 11,000 11,000Note 1: When sizing the external 24 VDC power supply, add 500 mA to the required total sensor current. TABLE 3:SERIES 155 FEATURES AND OPTIONSCalib. Opt.& EPA FlowOpt. Optional Drift Control RedundantModel Input Alarm Paper Tape Check Loops Con?g.Number Power Relays Printer (Note 1) (Note 2) (Note 3)155Jr AC 4 NA NA 1 OPT155Jr DC 4 NA NA 1,2 OPT155A AC 4 NA STD 1,2 OPT155A DC 4 NA STD 1,2 OPT155B AC 4 NA STD 1,2 OPT155B-RM AC 4 OPT STD 1,2 OPT155B-RM DC 4 OPT STD 1,2 OPT155C-2 AC 8 NA STD 2,4 OPT155C-2 DC 8 NA STD 2,4 OPT155E-2 AC 8 NA STD 2,4 OPT155C-RM2 AC 8 OPT STD 2,4 OPT155C-RM2 DC 8 OPT STD 2,4 OPT155E-RM2 AC 8 OPT STD 2,4 OPTNote 1: This Feature has been designed primarily for use with one Mass Flow Meter such as theaverage of several K-BAR 24 Mass Flow Elements, the average of several Single-Point InsertionMass Flow Elements or a single In-Line Mass Flow Element. If an acknowledgment relay is desired,one additional input channel, alarm relay and METER is required.Note 2: When a Kurz In-Line Mass Flow Element is used with a Series 730 Control Valve and anisolated external set-point reference (4-20 mA) is supplied, one 4-20 mA input channel and oneMETER must be allocated for each control loop.Note 3: The customer must specify a Redundancy Kit (see 155 Accessories).S E R I E S 1 5 5 M A S S F L OW C O M P U T E R SORDERING INFORMATIONPAGE 3Kurz Instruments, Inc. 2411 Garden Road, Monterey, CA 93940 Tel 800-424-7356Fax 831-646-8901 www.kurzinstruments.com e-mail: sales@kurzinstruments.comTABLE 2:SERIES 155 AND MASS FLOW ELEMENT SELECTION CHARTNumber of Number of MaximumNumber of 4-20 mA 4-20 mA SensorMass Flow Sensor Loop-powered Flow Temp. CurrentModels Type Flow Channels Channels Channels (MA)452, K-BAR 24, FD-MT 1 0 0 500542, FD-HHT502-40 -96454FT , FD-MT 0 1 1 500504FT -40 -96 FD-HHTK-BAR 2000452T, 542T, FDT-MT 1 0 1 520K-BAR 24 FDT-HHT502-6A -32 MD 1 0 0 400522, 532, K-BAR16504FT -6A -32 MD 0 1 1 400410, 510 CD 1 0 0 250BBototBototBSUMMARY OF FEATURESFeature Feature Description1 Number of 4-20 mA Outputs2 Number of 0-5 VDC Analog Outputs3 Alarm Relays, Flow Control Drivers, Pulsed Outputs4 Built-in Calibrators5 Input Power6 Terminal Communication and Data Ports7 Printer Option8 Series 155 Software Version/Chip Set9 Number of Loop-Powered Mass Flow Sensor Input Channels10 Number of 4-20 mA Mass Flow, Temperature or Reference InputChannels11 Number of METERSPART NUMBER GENERATION PROCEDUREWith the selected Parent Number, specify the entire Part Number by selecting an Optionfor each Feature as shown in the example below.750101Parent Number F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F110 4 0 1 0 5 0 4 0 1 0 1 8 8 0 1 0 1 0 0 0 1FEATURE 1: NUMBER OF 4-20 mA OUTPUTSNumber ofOption Outputs Models Description88 0 All No 4-20mA Outputs04 1 All05 2 All Loop-powered AC/DCisolated, or self-powered AC non-isolated, 06 4 155C-2, user selected.07 6155C-RM2,155E-2,08 8 155E-RM2FEATURE 3: ALARM RELAYS, CONTROL DRIVERS, PULSED OUTPUTS (Continued)Option Description (Note 1)08 Eight alarm relays, two ?ow control drivers for Kurz 730 control valves;Models 155C-2, 155C-RM2, 155E-2, 155E-RM2.09 Four alarm relays, two ?ow control drivers for Kurz 730 control valves;Models 155Jr (DC), 155A, 155B, 155B-RM.10 Eight alarm relays, four ?ow control drivers for Kurz 730 control valves;Models 155C-2, 155C-RM2, 155E-2, 155E-RM2.11 Eight alarm relays, two ?ow control drivers with analog control signal fordriving variable speed motors and position-input vanes and dampers,and valves 0-10 VDC up to 20 mADC output. Models 155C-2, 155C-RM2,155E-2 and 155E-RM2.12 Four alarm relays, two pulsed ?ow totalizer outputs, Models 155Jr, 155A,155B, 155B-RM13 Four alarm relays, one ?ow control driver, and two pulsed ?ow totalizer outputs; Models 155Jr, 155A, 155B, 155B-RM.14 Eight alarm relays, eight pulsed ?ow totalizer outputs; Model 155C-2, 155C-RM2, 155E-2, 155E-RM2.15 Eight alarm relays, two ?ow control drivers, four pulsed ?ow totalizer outputs; Models 155C-2, 155C-RM2, 155E-2, 155E-RM2.Note 1: When alarm or alarm relays are ordered the 4th (Models 155Jr, 155A, 155B, 155B-RM)or 8th (Models 155C-2, 155C-RM2, 155E-2, 155E-RM2) alarm relay is automatically reserved forthe Global Sensor “Kick-Out” feature.FEATURE 4: BUILT-IN CALIBRATORSOption Description04 Built-in Electronic Calibrator. All versions of Model 155Jr.06 Built-in Variable input (0-5 VDC) Electronic Calibrator with externally activated Flow Drift Check Circuit. User to initiate “zero” and “span” timingcycles by providing a contract closure for “zero” and one for “span”. Includesability to set one or two alarm relays to provide acknowledgement that“zero/span” Drift Check Circuit is operative (requires one additional relay,METER and input channel). Meets EPA requirements for ?ow monitors.Models 155A, 155B, 155B-RM, 155C-2, 155C-RM2, 155E-2, 155E-RM2 only. FEATURE 5: INPUT POWEROption Description01 115 VAC 50/60 Hz; all Models.02 230 VAC 50/60 Hz; all Models.03 Isolated, 24 VDC, Models 155Jr, 155A, 155B-RM, 155C-2, 155C-RM2, FEATURE 6: TERMINAL COMMUNICATIONAND DATA PORTSOption Description88 RS-232C terminal communication port; echoes display/keypad and allows use of a computer terminal for programming, all Models. 01 RS-232C data port with standard output format and RS-232C terminal communication port as described above. Protocol furnished. All Models. This option must be ordered if a printer is ordered (Feature 7).03 RS-485 data port with standard output format and RS-232C Terminal communication port as described above. Protocol furnished. Models 155C-2, 155C-RM2, 155E-2 and 155E-RM2 only.S E R I E S 1 5 5 M A S S F L OW C O M P U T E R SPAGE 4FEATURE 3: ALARM RELAYS, CONTROL DRIVERS, PULSED OUTPUTSOption Description (Note 1)88 No alarms, relays, or control driver outputs; all Models.05 Four alarm relays, (5 A. 24 VAC/VDC); Models 155Jr, 155A, 155B, 155B-RM.06 Eight alarm relays (5 A. 24 VAC/VDC); Models 155C-2, 155C-RM2, 155E-2, 155E-RM2.07 Four alarm relays, (5 A. 24 VAC/VDC), one ?ow control driver for Kurz 730 control valve; Models 155Jr, 155A, 155B, 155B-RM.Kurz Instruments, Inc. ¦ 2411 Garden Road, Monterey, CA 93940 ¦Tel 800-424-7356Fax 831-646-8901 ¦ www.kurzinstruments.com ¦ e-mail: sales@kurzinstruments.comFEATURE 2: 0-5 VDC ANALOG OUTPUTS (NOTE 1)Option Number of Outputs Description88 001 1 ALL02 204 406 6 155C-2, 155C-RM2, 155E-2, 155E-RM208 8Note 1: The number of analog 0-5 VDC outputs must be equal to or the number of 4-20 mAoutputs selected in Feature 1.ORDERING INFORMATIONUsing the Series 155 Part Number/Order Sheet:A Enter the complete Series 155 Part Number (Section A).B Enter the accessories Part Numbers.C Fill out the con?guration chart (Section B).D Contact the Kurz Representative or the Kurz Factory to place the order or to obtain additional information.FEATURE 7: PRINTER OPTIONOption Description88 No printer.05 Paper Tape Printer, requires that Feature 6, Option 01 (RS-232C Data Port)must also be ordered. The printer is mounted on the front panel.Models 155B-RM, 155C-RM2 and 155E-RM2.FEATURE 9: NUMBER OF LOOP-POWERED MASS FLOW SENSOR INPUT CHANNELSDescriptionEnter the number of input channels required for the loop-powered mass ?ow sensorsbeing used with a Series 155. Enter two (2) digits. See Table 1 for the maximum num-ber of input channels for each Model and the power supply current capability. Also seeTable 2.FEATURE 10:NUMBER OF 4-20 mA INPUT CHANNELSDescriptionEnter the number of input channels required for the 4-20 mA mass ?ow, temperatureor reference inputs. Enter two (2) digits. (Enter 00 if no 4-20 mA inputs are required). See Table 1 for the maximum number of input channels for each Model. These inputsmust be isolated from earth ground unless the Model 155 is used to supply the power.FEATURE 11: NUMBER OF METERSDescriptionsEnter the total number of METERS required for the application. Enter two (2) digits.See Table 1 for the maximum number of METERS for each Model.SERIES 155 ACCESSORIESPart Number Description170098 Stainless Steel Identi?cation Tag, maximum of 4 lines of 32 characterseach, 1.25" x 3". Specify information with order.700185-01 Model 185-4, RFI, EMI and Surge Protection Enclosure, for up to 5two-wire circuits, NEMA 4 painted steel, 8"L x 6"W x 4"D.700185-02 Model 185-8, RFI, EMI and Surge Protection Enclosure, for up to 10two-wire circuits, NEMA 4 painted steel, 8"L x 6"W x 4"D.700185-03 Model 185-20, RFI, EMI and Surge Protection Enclosure, for up to 20two-wire circuits, NEMA 4 painted steel, 14"H x 12"W x 6"D.700185-04 Model 185-2 RFI, EMI and Surge Protection Enclosure for up to 2 two-wire circuits. NEMA 4/7 painted aluminum, wall-mounted.700011-01 Rack Mounting Kit for one Model 155Jr Mass Flow Computer,10.5"H x 19" EIA Panel.700011-02 Rack Mounting Kit for two Model 155Jr Mass Flow Computers,10.5"H x 19" EIA Panel.S E R I E S 1 5 5 M A S S F L OW C O M P U T E R SFEATURE 8: SOFTWARE VERSION/CHIP SETOption Description01 Current software, includes Flow Control, VTM; English units. 11 Current software, includes Flow Control, VTM; Metric units. 02 Current software, includes Flow Control, VTM; “Flow Perfect” Multi-PointArray Correction Factor with “Kick-out Count”; English units. 12 Current software, includes Flow Control, VTM; “Flow Perfect” Multi-PointArray Correction Factor with “Kick-out Count”; Metric units.PAGE 5SPECIFICATIONSInput Channels:18.2 bit resolution0 to 5 VDC, 13.2 bit accuracy, ±30 ppm/°CAnalog Outputs:Resolution and Accuracy: 12 bit4-20 mA, Isolated (500 VAC or 707 VDC), 7 to 50 V compliance: at 24 VDC Rmax = 850 O Non-isolated, Rmax. = 400 O, ±110 ppm/°C0-5 V: 250 O min. load impedance ±30 ppm/°CMeasurement Rate: 0.1 s/channel + 0.2 SFilter Time Constant:0-3600 SLCD Display Update: Every 2 secondsSerial Port Baud Rate: 9,600Relays: 5 A, 24 VAC/DC, sealedEnvironment: –25 to 60°C, 10 to 90% RH, noncondensingPower: 115/230 VAC ± 10% 50/60 Hz; 24 VDC ± 10% Safety Approvals:Non-Incendive IEC 79-15, Ex nC II T4 (Cl. I , Div. 2, GPS. A, B, C, D, T4); CSA; EMI Approvals:CE compliance: light industrial; (EN 50081-2) for emissions, heavy industrial(EN 50082-2) for immunity and (EN 61000-4-5) for surges, all Models.SERIES 155 ACCESSORIES (Continued)Part Number Description700012-02 Dual Mass Flow Computer Redundancy Kit, includes Remote FlowElement Terminal Junction Box, cables, conduit, and conduit ?ttings.Enclosure must be located within two feet of Mass Flow Computers.Models 155C-2, 155C-RM2, 155E-2 and 155E-RM2. AC or DC input power700012-04 Dual Mass Flow Computer Redundancy Kit, for Models 155Jr, 155A and155B-RM. AC or DC input power.Kurz Instruments, Inc. 2411 Garden Road, Monterey, CA 93940 Tel 800-424-7356Fax 831-646-8901 www.kurzinstruments.com e-mail: sales@kurzinstruments.comOUTLINE DRAWINGS1/2" FNPT hub3X.31 x .50 slot4X4.666.508.122.164.002.252.258.508.941.81 .564X4.503.389.259.125.9411.253/4" FNPT hub2X6.922.5010.628.001/2" FNPT hub.31 x .50 slot4X12.133.503.502.5612.6212.94.564X3.8116.2515.759.0016.25 8.631" FNPT hub2X8.643.3014.5612.881/2" FNPT hub.31 x .50 slot4X3.503.505.7816.0716.94 16.58Model 155Jr, Parent No. 750101 Model 155Jr-ExW, Parent No. 750105Model 155A, Parent No. 750206 Model 155A-ExW, Parent No. 750208Model 155B, Parent No. 750235 Model 155B-RM, Parent No. 750237NET WT. 4.0 lbs.SHIP WT. 6.0 lbs.NET WT. 23 lbs.SHIP WT. 29 lbs.NET WT. 72 lbs.SHIP WT. 77 lbs.NET WT. 20 lbs.SHIP WT. 25 lbs.NET WT. 21 lbs.SHIP WT. 27 lbs.NET WT. 11 lbs.SHIP WT. 13 lbs.PAGE 6™INC.INSTRUMENTS.4 x .28 slot4X3 in. min. cableclearanceTelescoping slide,20.8" travel,2X8.8 5.81.5 19.018.217.21.3Kurz Instruments, Inc. ¦ 2411 Garden Road, Monterey, CA 93940 ¦Tel 800-424-7356Fax 831-646-8901 ¦ www.kurzinstruments.com ¦ e-mail: sales@kurzinstruments.comOUTLINE DRAWINGS™INC.INSTRUMENTS™INC.INSTRUMENTS0.75" FNPT hub6.77.26.820.021.64.0 4.0 4.020.018.56.5ø.41 thru4X2.6HINGE SIDE6.313.24.01.25" FNPT hub3X™INC.INSTRUMENTS™INC.INSTRUMENTS0.75" FNPT hubHINGE SIDE24.022.56.52.68.77.214.330.031.64.8 4.8 4.8 6.813.2ø.41 thru4X4.81.25" FNPT hub3X™INC.INSTRUMENTS.4 x .28 slot4X3 in. min. cableclearance1/2" MNPTRomexcable clamp1" MNPT Romex cable clamp, 3XTelescoping slide,20.8" travel,2X8.8 5.819.018.317.2 17.04.93.4 3.4 3.4 3.41.5FRONT VIEW SIDE VIEW REAR VIEW1.3Model 155C-2, Parent No. 750257Model 155E-2, Parent No. 750272Model 155C-RM2, Parent No. 750258Model 155E-RM2, Parent No. 750278NET WT. 48 lbs.SHIP WT. 55 lbs.NET WT. 75 lbs.SHIP WT. 90 lbs.NET WT. 25 lbs.SHIP WT. 32 lbs.PAGE 7Kurz Instruments, Inc. ¦ 2411 Garden Road, Monterey, CA 93940 ¦Tel 800-424-7356Fax 831-646-8901 ¦ www.kurzinstruments.com ¦ e-mail: sales@kurzinstruments.comThe leader in Mass FlowTechnology for Process andEnvironmental MeasurementsKurz Instruments, Inc.2411 Garden Road, Monterey, CA 93940800-424-7356 831-646-5911 Fax 831-646-8901w.ww kurzinstruments.come-mail: sales@kurzinstruments.comIMPORTANT NOTICE: Speci?cations are subject to change without notice. © 1998 Kurz Instruments, Inc. DCN 367001 REV. E???????????????©
Most popular related searches