DILO - Model C4-3-033-R400 -C4-FN Gas Leak Detector
The cordless battery-operated LEAKSPY C4 precisely measures the C4-FN concentration in air by means of a non-dispersive infrared sensor (NDIR sensor) and indicates the value on a graphic display in ppm. The device allows precise localisation of leaks by searching the highest C4-FN concentration.Thanks to the high resolution and detection limit, it is also possible to carry out integral measurements as well as measurements to determine the resolution and detection limit by means of this device. To protect the device from particles the sensor is equipped with a filter which can be cleaned and/or exchanged easily by the operator. In case there is C4-FN contamination already existing, the LEAKSPY C4 can be set to this value. Thus, it is possible to detect leaks even in already contaminated areas. The C4-FN concentration is indicated in ppm as well as by an audible signal.Most popular related searches
NDIR sensor
NDIR hydrocarbons
volatile organic compounds
gas leak detection system
volatile organics
infrared sensor
sensor system
particle sensor
gas leak
leak detection
To protect the device from particles the sensor is equipped with a filter which can be cleaned and/or exchanged easily by the operator. In case there is 3M Novec 4710 contamination already existing, the LEAKSPY C4 can be adjusted to this value. Thus, it is possible to detect leaks even in already contaminated areas. The 3M Novec 4710 concentration is indicated in ppmv as well as by an audible signal.
- Detection of leaks up to 3 g / year
- Quick response time
- No cross sensitivity to moisture and most volatile organic compounds (VOCs)
- Small, lightweight, easy to use
- A shoulder belt facilitates mobile and ergonomic working
- Battery-operated (operating time > 12 hours)
- Exchangeable accumulator (parallel loading of a second accumulator in separate charging unit possible)
Technical data:
- Dimensions: Width 125 mm, Height 142 mm, Length 280 / 555 mm (with / without measuring sensor)
- Measuring sensor length: 300 mm
- Weight: 1.580 g
- Power supply: lithium ion batteries (operating time > 12 hours)
- Measuring range: 0 – 1.000 ppm, (3M Novec 4710)
- Detection limit: 3 ppmv (3M Novec 4710)
- Sensitivity: 3 g 3M Novec 4710 /year
- Accuracy: < 50 ppmv ±2 ppmv; 50 - 100 ppmv ±5 ppmv; 100 - 1000 ppmv ±2 %
- No cross sensitivity to moisture (0 - 100 % relative moisture, non-condensing) and volatile organic compounds
- Indication accuracy: 1 ppmv
- Indication unit: ppmv, g/y, cc/s
- Operating temperature: 0 °C to +50 °C
- Storage temperature: -10 °C to +60 °C
- Measuring principle: non-dispersive infrared sensor (NDIR)
- Response time T90: < 1s
- Temperature and pressure compensated
- Indication: graphic display + audible signal
Standard equipment:
- Shoulder belt
- Measuring sensor extension (length: 1 m)
- Carrier case
- Battery charger
- 1 accumulator
- Separate charging unit
- Operating manual