- Home
- Companies
- Primary Flow Signal, Inc. (PFS)
- Products
- PFS - Model HVT-CI, HVT-DI - Cast ...
PFS - Model HVT-CI, HVT-DI -Cast Iron/Ductile Iron Venturi Flow Meters
The HVT-Halmi Venturi Flow Element in Cast Iron and Ductile Iron form is offered exclusively by Primary Flow Signal, Inc. for the highest accuracy and reliability for flow measurement of pressurized line fluids, including liquids and gases, as well as high-viscosity line fluids, solids-bearing line fluids, and harsh or contaminated line fluids.
The Cast Iron (HVT-CI) is well proven in municipal water and wastewater flow measurement and control applications, as well as air and other gases.
The Ductile iron (HVT-DI) version is available for higher line pressure applications.
Flow Control
The HVT design is optimal for use with close-coupled butterfly valves to form highly efficient and effective flow rate controllers for filter effluent control. See Rate of Flow Controllers for more details.
Solids Bearing Flow
The HVT design is also available configured with remote diaphragm seals making sewage flow measurement cost effective, accurate, and reliable without the concern for blocked pressure taps. See Sealed Meter System datasheet for more details.
Complete Section
For turnkey installation a PFS Flow Master system can be provided along with any dP measurement device providing fully integrated control, management and reporting capabilities.
+/- 0.50% Uncalibrated Uncertainty
Low Loss, Municipal & Industrial Applications
- Line size: 4 to 96 inches.
- Head loss % of Differential: 3.50 to 10.0 percent
- Recommended pipe Reynolds number: Greater than 75,000 for basic accuracy
- Line Size: 4 to 96 inches. Larger sizes available upon request.
- Head loss % of Differential (Venturi): 3.50 to 10.0 percent
- Basic Accuracy (% of Total): +/- 0.25 (Calibrated) +/- 0.50 (2 Sigma) (Uncalibrated)
- Minimum pipe Reynolds number: Must be greater than 75,000
- Required Straight Piping: Consult datasheet for required US & DS piping based on your specific application
- Beta Range: 0.30 through 0.75
- Useful Service Life: Very Long
- Service Functional Limits: Clear liquid, gas, contaminated and solid-bearing line fluid
- Applications: WTP Filter Effluent Rate of Flow Control, Special Lay-lengths to fit existing piping constraints, Potable Water, Water Treatment Plant, Wastewater Treatment Plant
- Common Materials: Cast Iron or Ductile Iron body with 304 or 316SS throat