HASLER Smart Control Modul SCM-3 may be used in every HASLER® Weigh Belt Feeder. The SCM-3 is a controller module including regulation and control functions. It receives the information and signals directly from the force sensors: weighing, speed and index.
Most popular related searches
weigh belt feeder
belt feeder
weigh feeder
electrical safety
dosing system
weigh feeder controller
flow calculator
flow regulation
flow regulator
It performs also the calculations of flow – totalization – regulation command.
- Easy to install, use and maintain
- Galvanically separated outputs
- Modular system
- Industrial wiring
PDU and mobile application
The SCM-3 is supplied with a Process Display Unit offering a 5-inch touch screen and 16.7 million colors. As an option a mobile application is proposed.
Console functions
- Multilingual mode (Latin, Cyrillic & Chinese). 8 languages: French, English, German, Italian, Spanish, Portuguese, Russian and Chinese.
- Visualization of the inputs / outputs
- Menus in full wording
- Flow display in graphical curves
- Timestamp of alarms
- Embedded support
Compact package engine + controller
- Electronic and mechanical associated on each feeder
- Reduced field wiring.
- Connection and maintenance without disassembly
- Local/Remote
Soft tool :
- Diagnosis for maintenance and performance optimization
- Remote maintenance
Weight converter :
- Adds a second weight measurement point
- Connects a SFT digital weight sensor
Maintenance assistance :
- Inox frame removable
- I/O cards + Central Processing Unit disconnectable
- Immediate visualization of I / O and other functions of the module.
- Sub-D connectors.
Each dosing equipment is controled by a dedicated SCM3, for continuous or batch dosing applications. Potential use of standard components for I/O modules.
Communication protocol- Modbus TCP (Ethernet)
- Modbus RTU
- Profibus DP
- Profinet
- Ethernet IP
Power requirements
- Supply voltage : 100VAC to 230 VAC
- Supply frequency : 47 – 63 Hz
- Max. Power Consumption : 100 W
Dedicated Inputs / Outputs
- Digital Inputs (standard) (i.e., 24VDC...) : 8 8
- Digital Outputs : 4 8
- Digital Inputs for speed and index acquisition : 4
- Analog Input : 1 1
- Analog Output :2 2
Environmental ratings
- Area Classification : General Purpose
- Operating Ambient Temp. : -20°C to 60°C
- Storage Ambient Temp : -25°C to 70°C
- Operating Altitude : < 3000m
- Max. Humidity : 95% at 25°C without condensation (DIN 40040 Class F)
- Degree of Protection : IP65
Remote Inputs / Outputs
- Digital Inputs :
5 – 24 – 48 VDC / 24 – 120 –230 VAC - Digital Outputs :
5 – 24 VDC / 230 VAC / Relay SPST-DPDT - Analog Inputs / Outputs :
0 - 20 mA / 4 - 20 mA / 0 – 10 V
Dimensions of PDU
- Height : 166 mm
- Width : 116 mm
- Depth : 52mm
Dimensions of SCM3-P
- Height : 313 mm
- Width : 151 mm
- Depth : 211 mm
Electrical Standards
- General electrical emissions : EN50081-2
- General Electrical Immunity : EN50082-2
- Electrical safety : EN61010-1
Alternative
- SCM2 is also available in a feeder integrated version : FIELD
- Ref. to Technical Sheet SCM2-F.260.001.E.