Model FGC-1050 -Gas Chromatograph

SHARE

Determination of volatile organic compounds in water (drinks), detection of alcohol content in blood, indoor air pollutant detection (TVOC), analysis of liquor flavor components, transformer oil analysis, detection of residual solvents in pharmaceuticals, analysis of high purity gases, residues in medical equipment Determination of ethylene oxide. The main units of chromatograph are: liquor factory, other wineries, petrochemical, liquefier gas plant, coal industry, environmental testing, testing station, judicial appraisal center, public security system, food factory, quality inspection department, water supply factory, pharmaceutical factory, Pesticide plants, gas plants, chemical plants, packaging plants, paint plants, honey factories, chemical industry and other major chemical components, etc. need to use gas chromatograph, liquid chromatograph.

Most popular related searches
  • The gas chromatograph adopts large liquid crystal Chinese display, which is intuitive to operate. The instrument has self-diagnosis, power-off protection, file storage and recall, and eighth-order program temperature heating.
  • The gas chromatograph has a separate vertical heating capillary sampling system, which minimizes the influence of the vaporization chamber on the column chamber and improves the adaptability to various syringes. The capillary system has adjustable tail blow, diaphragm, adjustable cleaning and adjustable split ratio.
  • The new FID has high sensitivity and can conveniently handle the loading and unloading of nozzles and ion collectors. With six independent temperature control zones, each vaporization chamber, detector and amplifier are designed with modules, which is convenient and simple to install and replace.
  • The chromatographic column box has large capacity, and can be installed with capillary tube and packed column at the same time. It has three independent injectors. According to the analysis requirements, the gas and liquid inlet can be installed, and the installation of 0.53 wide-caliber capillary column can be easily completed. It is also possible to increase the six-way valve injection, the reformer unit, etc. according to the analysis requirements, and to realize the series and parallel operation of the detector.

Temperature control index

  • Temperature control area: column box, sampler, detector
  • Temperature control range: 5 °C ~ 450 °C (increment 1 °C) at room temperature
  • Temperature control accuracy: better than ± 0.1 °C
  • Program temperature: Eight-order rate 0.1 ° C ~ 40 ° C / min (increment 0.1 ° C)