Changsha Friend Experimental Analysis Instrument Co.,Ltd
9 products found

Changsha Friend Experimental Analysis Instrument Co.,Ltd products

Chromatograph

Special Gas Chromatograph for the Determination of Methyl Tert-Butyl Ether (MTBE)

Methyl tert-butyl ether, abbreviated as MTBE (methyl tert-butyl ether), is a colorless, transparent, low viscosity, volatile liquid with a special odor and an organic ether content of 18.2% oxygen. Its steam is heavier than air and can spread along the ground and burn when it coexists with strong oxidants. The purity of MTBE is about 97% to 99.5%, and the molecular formula is: CH3OC (CH3). MTBE is a high octane gasoline component with a base octane number of RON: 118, MON: 100, which is an excellent gasoline high octane additive and antiknock agent. MTBE and gasoline can be mutually dissolved in any proportion without delamination. When blended with gasoline components, there is a good blending effect, and the blended octane number is higher than its net octane number. MTBE has a relatively high oxygen content and can significantly improve vehicle exhaust emissions.

Gas Chromatograph for the Determination of Isooctyl Nitrate

Isooctyl nitrate Other names: 2-ethylhexyl nitrate, isooctyl nitrate English name: 2-Ethylhexyl nitrate; Isooctyl nitrate CAS RN: 73513-43-6 Molecular formula: (C8H17O) NO2 Molecular weight: 175.228 Product performance: Improve the cetane number of diesel, improve the combustion performance of diesel, shorten the ignition time, reduce the ignition point, improve the dynamic performance of the locomotive thermal conditions, and the fuel saving effect is very obvious. Uses: Used in diesel fuel, especially in secondary processing diesel to increase its cetane number. The effect of addition varies depending on the base oil. Generally, 0.1%-0.3% isooctyl nitrate is added to increase the cetane number by 2-9 units. It can also be used as an organic solvent. Packing, storage and transportation: Packed in 200L packaging drum, net weight 193kg. It should be stored in a cool, dry and ventilated place to prevent exposure, heavy pressure and rain. Similar foreign products: DH-3; ECA-8478.

Dimethyl Ether Special Chromatographic Analyzer

This product is mainly used in the detection of dimethyl ether in chemical plants and large liquefied gas stations using liquefied gas as raw material.

Gas Chromatograph

Determination of volatile organic compounds in water (drinks), detection of alcohol content in blood, indoor air pollutant detection (TVOC), analysis of liquor flavor components, transformer oil analysis, detection of residual solvents in pharmaceuticals, analysis of high purity gases, residues in medical equipment Determination of ethylene oxide. The main units of chromatograph are: liquor factory, other wineries, petrochemical, liquefier gas plant, coal industry, environmental testing, testing station, judicial appraisal center, public security system, food factory, quality inspection department, water supply factory, pharmaceutical factory, Pesticide plants, gas plants, chemical plants, packaging plants, paint plants, honey factories, chemical industry and other major chemical components, etc. need to use gas chromatograph, liquid chromatograph.

Gas Chromatograph

Determination of volatile organic compounds in water (drinks), detection of alcohol content in blood, indoor air pollutant detection (TVOC), analysis of liquor flavor components, transformer oil analysis, detection of residual solvents in pharmaceuticals, analysis of high purity gases, residues in medical equipment Determination of ethylene oxide. The main units of chromatograph are: liquor factory, other wineries, petrochemical, liquefier gas plant, coal industry, environmental testing, testing station, judicial appraisal center, public security system, food factory, quality inspection department, water supply factory, pharmaceutical factory, Pesticide plants, gas plants, chemical plants, packaging plants, paint plants, honey factories, chemical industry and other major chemical components, etc. need to use gas chromatograph, liquid chromatograph.

Lubricating Oil

Fully Automatic Polymer Oil Shear Stability Tester (Ultrasonic Method)

Fully automatic polymer-containing oil shear stability tester Applicable standard: SH/T0505, put a proper amount of polymer-containing sample in the energy-concentrating head, and subject it to one or more fixed-time ultrasonic shear treatment And the change in viscosity is measured according to the standard, and finally the viscosity drop rate of the sample is calculated. The oil is subjected to viscosity loss caused by ultrasonic shearing in the concentrator, and the shear stability is evaluated by the viscosity decreasing rate of the oil. The instrument is suitable for use with polymer-containing hydraulic fluids and internal combustion engine oils.

Lubricating Oil Low Temperature Brookfield Viscosity Tester

This instrument can measure the absolute viscosity of Newtonian liquid. Widely used in oils, paints, slurries, textiles, food, pharmaceuticals, adhesives, cosmetics and other production industries and research units. The instrument is accurate, fast, intuitive and simple, and has been selected by customers in various industries.

Cooperation Brand

Liquid Petroleum Product Hydrocarbon Analyzer

This standard applies to the determination of hydrocarbons (saturated hydrocarbons, olefins, aromatic hydrocarbons) in petroleum fractions with a boiling point below 315. Standard Test Method for Determination of Hydrocarbons in Liquid Petroleum Products by Fluorescent Indicator Adsorption. Test Method Determines saturates, olefins and aromatics in petroleum fractions that distill below 315°C.

Portable Dissolved Oxygen Meter

Fully watertight (IP67 waterproof rating), impact resistant instrument housing, and innovative dissolved oxygen electrode modules that can be replaced in the field. Dissolved oxygen and temperature can be measured simultaneously using YSI`s proven polarography technology and YSI`s global high-precision temperature model of thermistor technology. The new generation PE cover film provides faster reaction times and lower agitation dependence.