Technical Associates
47 products found

Technical Associates products

Water Monitors - New Products

TA - Drinking Water Safety Monitor

Model NEX-BETA-ABG-7 and 9 are radiation detecting water monitor /controllers for measuring of alpha, beta and gamma emitting radio nuclides. The electronics are microprocessor with LED/LCD display. The system is covered by TA`s full one year warranty. On-site service contracts available in many areas.

TA - Water and Effluent Discharge Radiation Monitor

Model NEX-BETA is a Beta detector water monitor /controller for measuring of Beta emitting radio nuclides. The electronics are microprocessor with LED/LCD display with plug in modules facilitating quick change or addition of functions at a later date. Modular design allows for rapid repair by module replacement in the field.

TA - Heavy Water Leak Detector

This monitor was originally designed for real time low-level detection of tritium in water in the industrial environment of nuclear power plants and has now been updated and adapted for environmental and scientific applications. Low MDA, reliability, ruggedness and simplicity of operation is what sets this monitor apart from less durable laboratory type of the equipment.

TA - Tritium in Water Monitor

This system consists of a small light tight detector assembly which is interfaced with the sample via male 1/4` pipe fittings with the readout and processor assembly via two BNC connectors. The sample is passed through a deionizer and filter and thence to the detector assembly, where it is viewed by a matched pair of photo multiplier tubes. The table top or rack mounted processor and display portion of this system conditions and analyzes the output from the photo multiplier tubes by pulse height and coincidence, thereby permitting the system to eliminate counting most background (noise) counts.

TA - Multi Detector Water Monitor and Controller System

Model NPP-H2O is a multi detector water monitor /controller for simultaneous measuring of Alpha, Beta and Gamma-emitting radio nuclides. The electronics are microprocessor with color LCD display. The pre-amps are plug in modules allowing quick change, addition of functions, and rapid repair in the field. The modular system is covered by TA`s unique exchange warranty system in addition to the full one year warranty. On-site warrantees available in many areas.

TA - Drinking Water Radiation Safety Monitor

Model NEXGEN-SSS is a multi-detector water monitor /controller for simultaneous measuring of alpha, beta and gamma-emitting radio nuclides. The electronics are microprocessor with color LCD display. The pre-amps are plug in modules allowing change or addition of functions at a later date, and allow rapid repair by module replacement in the field. The modular system is covered by TA`s unique exchange warranty system in addition to the full one year warranty. On-site warrantees available in many areas.

Air Monitors - New Products

TA - Air Monitor

The F-CARB-9 Air Monitors assure safety against airborne radioactivity contamination by means of constant check with alarm and record capability. It provides integrated exposure information and can provide hard copy via external printer or computer. It is a complete system but may be expanded per need with modules of the FM-9 series.

TA - Network Air Monitor

Model ABG-NET is a networkable or standalone Air Monitor. Each unit includes: Moving filter tape. Silicon or Scintillation Alpha particulate detector. Thin window Beta particulate detector. Ambient Gamma detector. Internal Data logger. USB or Ethernet Quick Connect. Networking software.

TA - Portable PET, Iodine, or Tc-99M DTPA Air Monitor for Gas & Particulates

The FM-9- ABNI uses a standard charcoal filter in TA`s unique quick change, no leak holder to trap any airborne Radio Iodine. The filter is under constant surveillance via a thin window scintillation detector. Air is drawn by a regulated pump through a three-foot inlet hose and exhausted via a flow meter through another three-foot hose. These may be extended to allow monitoring of hoods, glove boxes, stacks, etc. Time is recorded by an odometer type timer wired into the pump circuit. Portable PET, Iodine, or Tc-99M DTPA Air Monitor for Gas & Particulates. Use in Hospitals, Research Labs, Power Plants, National Labs. High Sensitivity, Constant Check with Alarm and Record capability. Integrated Exposure.

TA - Alpha and Beta Particulate Air Monitor

The FM-9-MA2 and FM-9-MAB2 Air Monitors utilize a solid state detector and two coordinated single channel analyzer windows. Utilizing two coordinated single channel analyzers the electronics will reject Radon pulses. The sample window (PHA allows the user to preset specific energy level for sample (eg. The “Radium A” peak), measuring Pu-239 or other Alpha emitters in the presence of significant or changing Radon-Thoron background. The count rate is shown on the front panel color monitor display both rate and integrated information. The user can select the operating modes: gross count, pulse height analyzing (PHA), or PHA with background subtract (PHA-SUB).