Aereon, part of Cimarron group articles
Project Details
- Location: Permian Basin
- Flow Rate HP: 10 MMSCFD
- HP Inlet Pressure (ΔP): 10-250 psig
- HP Smokeless %: 100% of flow
- Flow Rate LP: 1.0 MMSCFD
- LP Inlet Pressure (ΔP): 8 oz/in2
- LP Smokeless %: 100% of flow
- Heating Value: 1250 BTU/SCF
PROJECT DETAILS
Location:PermianBasin
FlowRateHP:1.5MMSCFD
HP100%Smokelessupto:750MCFD
HPInletPressure(ΔP):1psig
FlowRateLP:750MSCFD
LP100%Smokelessupto:450MCFD
LPInletPressure(ΔP):1oz/in2
Heating Value: 2,600 BTU/SCF
Pilot: Electronic Model 850
Solar Package
Install Year: 2017
Aereon’s Inferno Series flare is used here to burn off waste natural gas from a high-pressure separator and 6 s
PROJECT DETAILS
- Location: East Texas
- Flow Rate HP: 5.0MMSCFD
- HP Inlet Pressure(ΔP): <1psig
- Flow Rate LP: 300MSCFD
- LP Inlet Pressure(ΔP): 2oz/in2
- Heating Value: 1,600 BTU/SCF
- Pilot: Q-50
- Smokeless: Up To Ringelmann1
- Installed Y
Project Details
- Location: Marcellus
- Carbon Capacity: 3300 lbs
- Processing Rate: 2 trucks / day
- Electrical Class: C1D1
- HP: (2) 2HP Vacuum Pumps
- Voltage: 480 VAC
- Year Installed: 2016
- Emissions reduced: 25 tons / year
Aereon’sAir De
PROJECT DETAILS
- Location: PayneCounty, OK
- Flow Rate LP: 1.5MMSCFD
- LP Inlet Pressure(ΔP): 8-10oz/in2
- Heating Value: 2351 BTU/SCF
- Blower: 5 HP VS
- Info: Midstream Client
Aereon’s Cyclone Series Air Assist flare is used to maintain emission compliance by destroying co
Project Details
- Location: WestColorado
- FlowRateLP: 3.5MMSCFD
- LPInletPressure(ΔP): 1psig
- Heating Value: 900 BTU/SCF
- Gas Type: Methane
- Carbon Credit available: Yes
Aereon installed the HTF Thermal Oxidizer in an abandoned West Colorado coal mine with the capacity to oxidize up to 3.5
PROJECT DETAILS
- Location: Longstreet,LA
- FlowRate: 13,500-36,000lb/hr(2.9–7.8MMSCFD)
- SupplyPressure: 2psig
Aereon’sFIRECAT Thermal Oxidizer system is designed to destruct Acid Gas from a Midstream Client’s Processing Plant. The design of the system was based on an initial flow rate with expansion capacity availability. Our system was engineered to meet
PROJECT DETAILS
Location: Utica
Model: SentrySeriesMeVRU4.3L
Compressor: FloodedrotaryScrew
FlowRateHP: 150MSCFDPower: 70HP
InletPressure: 2-10Oz
DischargePressure: 175PSIG
Driver: CertifiedflexfuelNGengine
In this application Aereon’s Sentry VRU is used as part of the producers standard facility design. During the early production stage of a well, producing volumes are their highest, but often decline rapidly in the m
Project Details
- Location: Appalachian
- Basin/Marcellus
- Two x 2HP Rotary Vain Vacuum Pumps
- Max Operating PSI: 5 PSI
- Max Load: 1000 SCF Per Truck
Aereon’s Jordan Air Defender is a Patent Pending emissions control device. It is designed to reduce emissions from liquid loading operations by recovering VOC’s expelled from cargo trucks during loading events. This application consists of an Ac
The EPA has issued three final rules that will curb emissions of methane, smog-forming volatile organic compounds (VOCs) and toxic air pollutants such as benzene from new, reconstructed and modified oil and gas sources, while providing greater certainty about Clean Air Act permitting requirements for the industry.
The EPA’s amended and new regulations affecting methane (CH4) and VOC emissions from the oil and gas sector have been finalized and the new rules were published