- Emissions Monitoring - Flue Gas Analyzer
- Emissions Monitoring - Continuous Emission Monitoring System (CEMS)
- Emissions Monitoring - On-Site CEMS (UV-DOAS)
- Emissions Monitoring - Online VOCs Monitoring System (PID)
- Emissions Monitoring - VOCs Online Monitoring System
- Emissions Monitoring - FTIR Analyzer & System
- Emissions Monitoring - Temperature, Pressure & Velocity Monitor
- Emissions Monitoring - Dust Monitor
- Emissions Monitoring - Humidity Analyzer
- Air Quality & Industrial Park Monitoring - Air Quality Monitoring System
- Air Quality & Industrial Park Monitoring - Dynamic Calibrator
- Air Quality & Industrial Park Monitoring - Zero Gas Generator
- Air Quality & Industrial Park Monitoring - Micro Air Quality Monitoring System
- Air Quality & Industrial Park Monitoring - Ambient Particulate Monitor (ß Ray)
- Air Quality & Industrial Park Monitoring - Ambient Dust Monitor (Laser Scattering)
- Air Quality & Industrial Park Monitoring - VOCs Analyzer
- Air Quality & Industrial Park Monitoring - Enrichment Analyzer
- Air Quality & Industrial Park Monitoring - Open-Path FTIR Gas Analyzer
- Air Quality & Industrial Park Monitoring - Vehicle Exhaust Remote Sensing System
- Water Quality & Waste Water Monitoring - Analyzer
- Water Quality & Waste Water Monitoring - Sensor
- Water Quality & Waste Water Monitoring - Auto Water Sampler
- Process Analysis & Safety - In-Situ Laser Gas Analyzer
- Process Analysis & Safety - Extractive Laser Gas Analyzer
- Process Analysis & Safety - On-Site CEMS (TDLAS)
- Process Analysis & Safety - Hydrogen Analyzer
- Portable - Flue Gas Analyzer
- Portable - Portable FTIR Gas Analyzer
- Portable - Portable VOCs Gas Analyzer
- Portable - Portable Laser Gas Analyzer
- Analysis Module
- Lab Equipment
Hangzhou Chunlai Technology CO., Ltd. products
Air Quality & Industrial Park Monitoring - Air Quality Monitoring System
Zetian - Model AM-5900 - Zero Gas Generator (Portable)
The AM-5900 is an air source device that produces dry and clean air for use in dilution calibration systems, permeation furnace generation equipment, and also provides carrier gas for FID analysis equipment. The product has a built-in small oil-free air compressor, a three-stage water removal unit, a hydrocarbon removal unit, and a multi-stage impurity gas removal unit. It features a portable wheeled trolley case for flexible outdoor experimental use.
Zetian - Model AM-5401 - Portable Ozone Analyzer
AM-5401 portable ozone analyzer adopts the principle of untraviolet spectrohotometry and combines with advanced micro-processing technology to provide accurate and reliable low-concentration O3 detection of `ppb-ppm` level, which meets application requirements of atmospferic monitoring.
Zetian - Model EMOGA-5 - Odor Gas Continuous Emission Monitoring System
The EMOGA-5 can measure parameters such as methyl mercaptan, methyl sulfide, dimethyl disulfide, styrene, carbon disulfide, hydrogen sulfide, ammonia, trimethylamine, temperature, pressure, flow rate, humidity, etc., of which methyl mercaptan, methyl sulfide, dimethyl disulfide, styrene, carbon disulfide, hydrogen sulfide, ammonia and trimethylamine are measured by the characteristic absorption spectroscopy method; temperature by the platinum resistor (PT100) or the thermocouple, pressure by the pressure sensor and velocity by the Pitot differential pressure method, and humidity by the high temperature capacitance method. The characteristic absorption spectroscopy method can also measure benzene and toluene.
Zetian - Model OGA-100 - Odor Gas Analyzer
The OGA-100 Odor Gas Analyzer is an independently developed gas analysis product designed for online monitoring of odor gases from unorganized emission sources and main discharge outlets. Based on characteristic absorption spectroscopy and the PLS algorithm, it can simultaneously monitor various odor gases, including methyl mercaptan (CH4S), dimethyl sulfide (C2H6S), dimethyl disulfide (C2H6S2), styrene (C8H8), carbon disulfide (CS2), hydrogen sulfide (H2S), ammonia (NH3), trimethylamine (C3H9N), TVOC, and odor concentration (OU value). Additionally, other components such as SO2, NO, and NO2 can be included according to user requirements.
Zetian - Model AM-5 - Air Quality Monitoring System
AM-5 Continuous Automatic Online Monitoring System of Air Quality can real-time monitor the concentration change of general pollution factors in the air including SO2, NOX, O3, CO, particulate matter (PM2.5 and PM10), etc. According to the customer demand, aerosol, VOCs, NH3, halide (HF/HCl) and other special factors can be integrated. Combining with Five Meteorological Parameter Analyzer (temperature, humidity, wind direction, wind speed, air pressure), it can online monitor the environmental continuously for 24 hours and realize regional air quality assessment through data collection, storage and analysis.
Zetian - Model AM-5100 - SO2 Analyzer
The AM-5100 SO2 Analyzer, based on the Ultraviolet Fluorescence Principle and combined with advanced Micro-processing Technology, provides accurate and reliable low-concentration SO2 detection of `PPB~PPM` level, which can be applied to atmospheric monitoring and CEMS system (dilution method).
Zetian - Model AM-5200 - NOx Analyzer
Based on the Chemiluminescence Principle, the NOX analyzer adopts modular structure design and combines with advanced Microprocessing Technology to provide accurate and reliable low-concentration NOX detection of `PPB~PPM` level, which can be applied to atmospheric detection and CEMS system (dilution method).
Zetian - Model AM-5300 - CO Analyzer
Based on the Non-Dispersive InfraRed (NDIR) Technology, the CO Analyzer adopts modular structure design and combines with advanced Micro-processing Technology to provide accurate and reliable CO detection of “ppm” level, which meets application requirements of atmospheric detection.
Zetian - Model AM-5400 - Ozone Analyzer
AM-5400 Ozone Analyzer adopts the principle of Ultraviolet Spectrophotometry and combines with advanced Micro-processing Technology to provide accurate and reliable low-concentration O3 detection of `ppb~ppm` level, which meets application requirements of atmospheric monitoring.
Zetian - Model AM-5205 - Ammonia Analyzer
The AM-5205 Ammonia Analyzer adopts Chemiluminescence Principle, Equipped with external ammonia reformer and sampling system, the selectable range covers from 0-50ppb to 0-2000ppb, which meets application requirements of atmospheric detection. requirements of atmospheric detection.
