Only show results in Massachusetts? Ok

MtoZ Biolabs Environmental industry Services

  • MtoZ Biolabs - Metallomics Service

    MtoZ Biolabs offers metallomics analysis service using ICP-MS, which has characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of metals even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant metabolites can be hugely reduced, thus further increasing ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - Plant Metabolomics Mass Spec

    Based on Thermo Q Exactive and AB Q-TOF 5600 mass spectrometry systems, MtoZ Biolabs is proud to offer high-efficient and accurate plant metabolomics analysis service, specific to primary and secondary metabolism analysis. We provide custom service based on your specific research requirements, and assure comprehensive analysis service with the ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - disulfide bond analysis

    Disulfide bond is essential for protein molecules to maintain the correct advanced structure and maintain protein bioactivity. The distribution of disulfide bonds in antibody drugs is a direct structural characteristic of the drugs. Therefore, confirmation of disulfide bonds plays a very important role in the confirmation process of antibody drug ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - Flavone metabolomics

    MtoZ Biolabs offers targeted flavones analysis service using ACQUITY UPLC/TripleQuad5500 (Waters/AB Sciex), which has the characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of flavones even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - polyphenol metabolomics

    MtoZ Biolabs offers targeted polyphenols analysis service using ACQUITY UPLC/TripleQuad5500 (Waters/AB Sciex), which has characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of polyphenols even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - Acyl CoAs metabolomics

    MtoZ Biolabs offers targeted Acyl CoAs analysis service using ACQUITY UPLC/TripleQuad5500 (Waters/AB Sciex), which has characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of Acyl CoAs even in low abundance. Service details: http://www.mtoz-biolabs.com/acyl-coas.html

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - stable isotope labeling by amino acids in cell culture

    'Similar to SILAC technique, Dimethyl labeling is also an isotopic labeling method. However, Dimethyl labeling is a chemical labeling process, and labels lysine or the N-terminal amino acid residues on peptide, instead of labeling proteins. Except for the difference in labeling method, SILAC and Dimethyl labeling technique have comparable ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - sugar metabolomics

    A carbohydrate is a biological molecule consisting of carbon, hydrogen and oxygen atoms, usually with hydrogen to oxygen atom ratio of 2:1. Carbohydrates are important components of organisms, and play multiple roles in regulating various biological activities, such as cell recognition and protein secretion. MtoZ Biolabs has established a platform ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - edman degradation

    Edman sequencing method analyzes the protein N-terminal sequence in sequential Edman reactions. While mass spectrometry technology has been commonly used for protein analysis, Edman sequencing is still a powerful and irreplaceable method for protein N-terminal sequencing. As a well-established sequencing method, Edman sequencing provides more ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - precise label free quantification

    'Sequential Window Acquisition of all Theoretical fragment ions (SWATH) is a brand new mass spectrometry technology co-developed by Dr. Ruedi Aebersold research group (ETH Zürich) and AB SCIEX. SWATH data is an independent acquisition (DIA) technique. Unlike data dependent acquisition technique, which only selects certain MS spectrum for MS/MS ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - PTMs analysis

    'Post-translational modifications (PTMs) are covalent and usually enzymatic modifications on proteins. Common PTMs include phosphorylation, acetylation, ubiquitination, glycosylation, and so on. These PTMs can cause huge influences on protein structure, distribution, and function, hence, increasing the complexity of proteome to a greater extent. ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - disulfide bond prediction

    To meet specific research needs of our customers, MtoZ Biolabs provides disulfide bond analysis service at both single protein level and proteome level. We have optimized our sample preparation method to reduce the chance of in vitro disulfide bond exchange and maintain the native protein structure to the greatest extent. We have developed a ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - vitamins analysis

    MtoZ Biolabs has established a platform for analyzing multiple types of vitamins. With our well-established analytical platform and optimized sample preparation methods, we are able to accurately analyze over 70 types of vitamins even in low abundance.Visit http://www.mtoz-biolabs.com/vitamins.html for service details.

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - Fatty Acids GC-MS

    Based on GC/MS (7890A/5975C) technology and coupled with fatty acid standards, MtoZ Biolabs can identify and quantitate over 40 kinds of fatty acids in your sample. We guarantee accurate analysis of fatty acids molecules even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant metabolites can ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - mAB sequencing

    'Although hybridoma cells are immortalized, extensive passage of hybridoma cells may cause mutations on antibody genes, and hybridomas may loss their specificity to produce the correct antibody. Therefore, sequence information of antibody is of extreme importance for stable quality of antibody in large-scale industrial manufacturing. To solve this ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - antibody gene sequencing

    'Although hybridoma cells are immortalized, extensive passage of hybridoma cells may cause mutations on antibody genes, and hybridomas may loss their specificity to produce the correct antibody. Therefore, sequence information of antibody is of extreme importance for stable quality of antibody in large-scale industrial manufacturing. To solve this ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - quantitative proteomics

    'Proteomics is a large-scale study of proteins in a certain organism. Depending on specific research objective, there are many analytical techniques for proteomics study. To better meet our clients’ needs, MtoZ Biolabs is proud to offer 5 quantitative proteomics service, including Label-free, iTRAQ/TMT, SILAC, MRM, and SWATH. We also provide ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - Carotenoid quantification

    MtoZ Biolabs offers carotenoid analysis service using ACQUITY UPLC/TripleQuad5500 (Waters/AB Sciex), which has the characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of carotenoids even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant metabolites ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - meat biomarkers quantification

    MtoZ Biolabs offers meat biomarkers analysis service using ACQUITY UPLC/TripleQuad5500 (Waters/AB Sciex), which has characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of meat biomarkers even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

  • MtoZ Biolabs - Oxysterols profiling

    MtoZ Biolabs offers oxysterol analysis service using ACQUITY UPLC/TripleQuad5500 (Waters/AB Sciex), which has characteristics of high accuracy, specificity, and sensitivity. We guarantee accurate analysis of oxysterols even in low abundance. With our optimized sample preparation methods, interference from high-abundance dominant metabolites can be ...

    By MtoZ Biolabs based in MASSACHUSETTS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you