- Home
- Companies
- TSI Incorporated
- Products
- Aerosol and Dust Monitors
- Aerosol Generators & Dispersers
- Aerosol Neutralizers
- Cascade Impactors
- Certifier Flow Analyzers
- Cleanroom Particle Counters
- Environmental Air Monitors
- Filter Testers
- Flow Meters, Flow Sensors and Flow Analyzers
- Heat Stress Monitors
- Aerosol Generators & Dispersers
- Automated Filter Test
- Certification Instruments
- Chemical Characterization
- Combustion Gas Analyzers
- Critical Environments Monitors/Controllers
- Exposure Monitoring
- Indoor Air Quality
- Mass Flowmeters
- Particle Counters & Detectors
- Particle Sizers
- Respirator Fit Testing
- Thermal Anemometry
- Ventilation Test Instruments
- Aerosol and Dust Monitors
- Aerosol Diluters
- Environmental Particle Counters
- Condensation Particle Counters
- TSI OmniTrak™ Solution
TSI Incorporated products
Particle Sizers
Model 3302A - Aerosol Diluter
Our Aerosol Diluter reduces particle concentrations of high-concentration aerosols, providing a representative sample that meets the input requirements of the Aerodynamic Particle Sizer® (APS™) spectrometer. This APS accessory achieves dilution ratios of 100 to 1 and 20 to 1 using easy-to-change capillary tubes. Two diluters in a tandem configuration provide dilution ratios as high as 10,000 to 1. Engineered to provide very low particle loss in the 0.5- to 10-µm size range, the Aerosol Diluter is totally self-contained and requires no outside power or compressed gas.Conductive Silicone Tubing for Particle Transport
Conductive silicone tubing is critical for aerosol experiments because it reduces the build-up of static charge and minimizes particle loss to the tubing wall. TSI offers flexible, conductive tubing in four sizes to accommodate most experimental setups.Flow Splitter Model 3708
The Flow Splitter directs an aerosol sample to as many as four destinations at once. This accessory is especially useful when performing instrument comparison or calibration experiments. Smooth flow transitions provide equal flow distribution. Stainless-steel construction and an electropolished interior prevent the aerosol from being contaminated. The Flow Splitter has a 3/8-inch straight-tube inlet and four 1/4-inch outlets (outside diameters). Maximum total flow rate is 30 L/min.Tisch - Model 3306 - Impactor Inlet
The Impactor Inlet is an accessory for the Aerodynamic Particle Sizer® (APS™) spectrometer. It combines a single-stage impactor with a filter to take a size-segregated sample. It then directs a small, representative sample of the initial test aerosol (diluted at 80 to 1) into the APS spectrometer for size-distribution measurement. The inlet aerosol passes through a single-stage impactor (2.5 or 4.7 µm) and is collected with an afterfilter, which collects a sample for later mass or chemical analysis.
TSI - Model 3090 - Engine Exhaust Particle Size Spectrometer EEPS
The EEPS uses an array of sensitive electrometers, combined with three proprietary data inversion matrices, to provide real-time particle size data in 32 size channels. The data inversion matrices allow the researcher to optimize size distribution accuracy for specific particle types (soot, default and compact), and matrices can be applied at the time of measurement or in a post-processing environment. It does not include any built-in sample dilution, giving the user maximum flexibility and independence with respect to sample conditioning. It operates at ambient pressure to prevent evaporation of volatile and semi-volatile particles. Providing size distributions and number concentrations down to 1000 #/cm³ ten times a second, it has been proven to be a valuable tool for automotive emissions engineers and aerosol researchers.TSI - Model 3091 - Fast Mobility Particle Size Spectrometer
The FMPS spectrometer 3091 offers a total of 32 channels of resolution (16 channels per decade). It uses an electrical mobility measurement technique similar to that used in our SMPS™ spectrometer. However, instead of a CPC, the FMPS spectrometer uses multiple, low-noise electrometers for particle detection. This enables particle-size-distribution measurements in real time, providing the unique ability to visualize particle events and dynamic changes in particle size distribution. The FMPS spectrometer operates at a high flow rate (10 L/min) to minimize diffusion losses of ultrafine and nanoparticles. It operates at ambient pressure to prevent evaporation of volatile particles, and it requires no consumables. It is easy to transport, set up, and operate. Equipment be configured to measure single or multiple runs continuously for up to 12 hours in length. Its large, color VGA display and built-in control knob provide easy access to instrument features, set-up menus, and data displays.TSI - Model 3938 - Scanning Mobility Particle Size Spectrometer (SMPS)
The SMPS spectrometer is a nanoparticle sizer capable of measuring the size distribution of airborne submicron particles with accuracy and precision. It combines electrical mobility sizing with single-particle counting to deliver nanoparticle concentrations in discrete size channels. The size resolution capability of the SMPS is as high as 128 channels per decade, resulting in up to 192 channels in total. The SMPS Model 3938 is component-based, allowing users to customize their SMPS to match their experimental needs. Users may choose among three DMAs, seven CPCs, and two different neutralization techniques, enabling measurement from 1 nm - 1 um.Model 3321 - Aerodynamic Particle Size Spectrometer
The Model 3321 Aerodynamic Particle Sizer® (APS™) spectrometer provides high-resolution, real-time aerodynamic measurements of particles from 0.5 to 20 µm. This unique particle sizer also measures light-scattering intensity in the equivalent optical size range of 0.37 to 20 µm. By providing paired data for each particle, the APS spectrometer opens up exciting new possibilities for those interested in studying the makeup of an aerosol.
