Metrohm AG
Refine by
Families
11 products found

Metrohm AG products

Karl Fischer - KF Titrando System

Metrohm - Model 852 - 2.852.0050 - Titrando With Generator Electrode With Diaphragm

Coulometer including generator electrode with diaphragm, 801 Magnetic Stirrer, and complete volumetric titration cell. Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.

Metrohm - Model 860 KF - 2.860.0010 - Thermoprep for Thermal Sample Preparation

The 860 KF Thermoprep is designed for thermal sample preparation in Karl Fischer titration. Numerous substances cannot be analysed by direct Karl Fischer titration as they are not soluble, react with the Karl Fischer reagent or release their water only very slowly or not until heated to high temperatures. Using tightly sealed sample vials, the sample is inserted in the oven. The samples can be subsequently analysed by any volumetric or coulometric KF titrator.

Metrohm - Model 874 - 2.874.0120 - Oven Sample Processor Used for Automatic Thermal Sample Preparation

The 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples, or those that react with the KF reagent.

Metrohm - Model 874 - 2.874.0130 - Oven Sample Processor Special Vials

The 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples, or those that react with the KF reagent. This instrument can be modified to match customer-specific sample vessels. Please contact your Metrohm representative for further information.

Metrohm - Model MATi 04 - Fully Automated Coulometric KF Titrations

MATi 4 is a fully automated system for coulometric KF titrations with high sample throughput. Up to 160 samples in 6 mL vials can be placed on the sample rack of the Sample Processor. The sample is pipetted into an external coulometric cell and then titrated there. The system is controlled with the OMNIS software.



Metrohm - Model MATi 11 - Automated Volumetric KF Titration System including Sample Preparation

Fully automated system for volumetric Karl Fischer water content determination in up to 53 samples. This system is controlled with OMNIS software and consists of an 815 Robotic USB Sample Processor XL, a 901 Titrando, a Polytron PT 1300 D and extensive accessories. The samples are weighed out into beakers, sealed to protect against humidity and placed on the rack. Before the actual titration, a defined volume of KF reagent is added and the sample is pulverized with the help of a Polytron. The water that is released is titrated afterwards. Even samples of poor solubility, e.g., tablets, can be analyzed without difficulty with this method. The use of solubility promoters can be avoided in this way.

Metrohm - Model MATi 10 - Automated Volumetric KF Titrations

Fully automated system for volumetric Karl Fischer water content determination in up to 24 samples. The system is controlled with OMNIS software and consists of an 814 USB Sample Processor, a 901 Titrando and extensive accessories. The samples are weighed out into the beakers, sealed to protect against humidity and placed on the rack. Before the actual titration, they are dissolved in a defined volume of KF working medium, after which the water content is titrated. This method is particularly suitable for samples that dissolve readily in the KF working medium. In addition, solubility can be improved by using suitable solubility promoters.

Metrohm Karl Fischer - Model 901 - 2.901.0010 - Titrando for the Modern Titration Laboratory

The Karl Fischer Titrando for the modern titration laboratory. In addition to the Karl Fischer mode (KFT), the high-end titrator is also equipped with the SET mode and can thus perform titrations to a predefined endpoint. iTrode ready": As a result of the high-resolution, galvanic measuring interface – now also for the first time with additional digital measuring input for the intelligent "iTrodes" electrodes – it is additionally possible to perform pH measurements with a maximum of precision.



Metrohm - Model 852 - 2.852.0150 - Titrando With Generator Electrode Without Diaphragm

Coulometer including generator electrode without diaphragm and complete volumetric titration cell. Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary. Recommended coulometry measuring range: 10 µg - 200 mg absolute water. The 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration. For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.



Metrohm - Model 851 - 2.851.0110 - Titrando With Generator Electrode Without Diaphragm

Coulometer including generator electrode without diaphragm. Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary. Coulometric titrations are carried out easily and quickly with the 851 Titrando. Recommended measuring range: 10 µg - 200 mg absolute water. For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.